- Principe de mesure : piston annulaire
- Nominal pressure: PN 25 / 16K
- Longueur d'installation : 190 mm
- Nominal diameter: DN 25 mm With flanges JIS 16K
- Installation position: horizontal/ vertical pipe
- Max. flow rate (Qmax): 3’000 l/h
- Max. continuous flow rate (Qcont): 2’000 l/h
- Min. flow rate (Qmin): 75 l/h
- Max. temperature: 180°C
- Registration capacity: 10’000’000 l
- Min. readable amount: 0.1 l
- Max. deviation: ± 0.5 % of value
- Repeatability: ± 0.1 %